User manual

Automation Protocol Scheduled Commands
Miranda Technologies Ltd Page 255
CMD Param_1 Param_2 Param_3 - Optional
V4 %s, %s, …
Keyer Numbers or
Keyer Names in
Xplay, separated by
commas
|%x
Fade Rate
0 – Cut
Fade Rate in mS
|%x
Output
0 – Preview
1 – On air
Set Property V5
This allows properties to be set on IntuitionXG. For example the text or
image to be used within one or more template on one or more keyer can be
set. The property can be set to be changed on the preview or on air. The
default is for the property to change to be seen on air.
CMD Param_1 Param_2 Param_3 Param_4 - Optional
V5 %s, %s, …
Objects and
Properties
%s, %s, …
Values
%s, %s, …
Keyer Numbers
or Keyer
Names in
Xplay.
|%x
Preview or On Air
0 – Preview
1 – On Air (default)
Multiple properties can be set by separating each ‘Objects and Properties’,
‘Values’ with the ‘,’ character. The ‘Objects and Properties’ to be set are a
delimited list in the form “ObjectName.PropertyName”. The ‘Values’
indicate, for example, the text or image to be used for that object and name.
The keyers can be identified using the keyer number, or the keyer name used
in Xplay.
Example
To set
Object: Textbox1
Property: Text
Value: Hello World!
And:
Object: Image1
Property: ImageName
Value: XMS:Images.Headshots:Obama
On:
Keyers: 1, 2
Preview or On Air: On Air
V5 Textbox1.Text, Image1.ImageName|Hello World!,
XMS\3AImages.Headshots\3AObama|1,2|1