Cue V0
This sets a template to be cued onto a IntuitionXG keyer, which can be
identified using the keyer number, or the keyer name that is used in Xplay.
CMD Param_1 Param_2 Param_3
V0 %s
Keyer Number or
Keyer Name in
Xplay
|%x
Template ID Type
0 – Recall ID
1 – Name
2 – Embedded Page
|%s
Template ID
If the template ID is specified as ‘Name’, the name used as Param_3 can be
specified as the name of the page, template, panel or scene itself without any
category information (the ‘short’ name), or it can be specified as a fully
qualified name. Note that since ':' is a reserved character, a fully qualified
name would have to be written using escaped characters.
Example:
To cue keyer ‘1’ with an page "XMS:Pages.Demo:PG_Lower3rd":
V0 1|1|XMS\3APages.Demo\3APG_Lower3rd