CMD Param_1 Param_2 Param_3 Param_4
oK %1x:
Bank No.
%1x:
Program
No.
%02x:
Flags
00
%02: ADC Type
0 – Standard (or unknown)
1 – HDCD
The current program A/D converter type can be enquired using:
CMD Param_1 Param_2
oK %1x: Bank
No.
%1x:
Program No.
The response is in the form of the set command.
Set Program High Pass Filter Enable oL
This command sets the program DC blocking High Pass Filter (HPF) enable
for the main input channels of the Dolby Digital encoder:
CMD Param_1 Param_2 Param_3 Param_4
OL %1x:
Bank No.
%1x:
Program
No.
%02x:
Flags
00
%1: HPF Enable
0 – Disabled
1 – Enabled
The current program HPF enable can be enquired using:
CMD Param_1 Param_2
oL %1x: Bank
No.
%1x:
Program No.