User manual

Automation Protocol Easytext Commands
Miranda Technologies Ltd Page 204
Set Program Down-Mix Mode oD
This command sets the type of stereo program down-mix mode preferred by
the master engineer. Note that this may be used, overridden or ignored:
CMD Param_1 Param_2 Param_3 Param_4
oD %1x:
Bank No.
%1x:
Program
No.
%02x:
Flags
00
%02: Preferred Down-Mix Mode
0 – Not indicated
1 – Left total/Right total preferred
2 – Left only/Right only preferred
The current program down-mix mode can be enquired using:
CMD Param_1 Param_2
oD %1x: Bank
No.
%1x:
Program No.
The response is in the form of the set command.
Set Program Down-Mix Lt/Rt Centre Mix Level
oE
This command sets the nominal program down-mix level of the centre
channels with respect to the left and right channels on a left total/right total
(Lt/Rt) down-mix:
CMD Param_1 Param_2 Param_3 Param_4
oE %1x:
Bank No.
%1x:
Program
No.
%02x:
Flags
00
%02: Centre Mix Level
0 – +3dB 1 – +1.5dB
2 – 0dB 3 – –1.5dB
4 – –3dB 5 – -4.5dB
6 – -6dB 7 – –infinity dB
The current program down-mix Lt/Rt centre mix level can be enquired using:
CMD Param_1 Param_2
oE %1x: Bank
No.
%1x:
Program No.