User manual

Automation Protocol Audio Commands
Miranda Technologies Ltd Page 184
Enquire Rates j73
Transition durations can be requested with the following example.
CMD Function
j7 %01x
3
void EnquireRates()
{
remote_send("j73");
}
The information returned is:
Format Field Description
%c j Audio
%c 7 Enquire
%c 3 Rates
%03x Fade to silence duration 0 to 600
%03x A/B Mix duration 0 to 600
%03x Voice-over 1 Pair 1 fade duration
6
0 to 600
%03x Voice-over 1 Pair 2 fade duration
7
0 to 600
%03x Voice-over 2 Pair 1 fade duration
8
0 to 600
%03x Voice-over 2 Pair 2 fade duration
9
0 to 600
Transition durations are returned in fields.
Enquire Audio Follow Video j74
The audio follow video settings can be requested from the Oxtel unit.
CMD Function
j7 %01x
4
void EnquireAudioFollow()
6
Voice-over 1 for Imagestore 300, Imagestore HD-TV and Imagestore 750.
7
Voice-over 2 for Imagestore 300, Imagestore HD-TV and Imagestore 750.
8
Redundant for Imagestore 300, Imagestore HD-TV and Imagestore 750.
9
Redundant for Imagestore 300, Imagestore HD-TV and Imagestore 750.