User manual

Automation Protocol Audio Commands
Miranda Technologies Ltd Page 160
Inputs j0
Input parameters can be changed remotely to suit applications. Channels can
be adjusted, phase inverted, shuffled and selected via the command strings
listed below.
Control Input ‘j0’ Input Number Function Function Parameters
The command j0 instructs the Oxtel unit that a parameter of an audio input is
to be changed. The first parameter to be sent is the audio input number. Each
input consists of 4 channels (equivalent to one group or two AES pairs).
The input number 1, 2 or 3 relates to the physical inputs of the Easysound
such that:
Input A/B Mix Mode Two Voice-over mode
1 A Input Background Input
2 VO Input Voice-over 1
3 B Input Voice-over 2
The second parameter is the function that has to be performed.
Function Function CMD
Shuffle 0
Mute 1
Trim 2
Phase 3
Level 4
Source 5
Several functions have additional parameters Channel/Pair/Group, Channel.
These allow the user to assign values to several channels of audio at once.
If the ‘Channel/Pair/Group’ parameter is given a value of 1, only one
channel (indicated by ‘Channel Number’) will be set.
If the Channel/Pair/Group parameter is given the value 2, a stereo pair will
be affected. In this case the Channel Number dictates which pair is set,
Channel Number = 0 for the first pair and Channel Number = 2 for the
second pair.