User manual

Automation Protocol Extended Status Commands
Miranda Technologies Ltd Page 151
Get Input Status XX
This command returns the current status of the Imagestore 750, DSK-3901
and LGK-3901 input requested:
CMD Param_1
XX %1x: Input
Where the Imagestore 750 inputs are numbered in the following order.:
0: A
1: Fill 1
2: Key 1
3: B
4: Fill 2
5: Key 2
6: C
7: D
For the DSK-3901 and LGK-3901 inputs are numbered as follows:
0: Program In
1: Fill 1
2: Key 1
4: Fill 2
5: Key 2
The Imagestore 750 return uses the following format:
Format Field Description
%c%c Cmd XR
%1x Input Input enquired
%1x Status Status of input, 0=unlocked, 1=locked
%1x Standard Standard of input, 0 = PAL, 1 = NTSC, 2 = 1080i
59.94Hz, 3 = 1080i 50Hz, 4 = 720p 59.94Hz, 5 =
720p 50Hz, f = Unknown (e.g. no input connected)