User manual
Automation Protocol Extended Status Commands
Miranda Technologies Ltd Page 150
The values broadcast in the response are separated by spaces.
Format Field Description
%c%c Cmd XV
%05.1f Ambient Temperature In degrees Celsius. The worst case
temperature measurement
%05.1f CPU Temperature In degrees Celsius
%05.1f KID Temperature In degrees Celsius
%05.1f CPU FPGA Temperature In degrees Celsius
%05.1f SID Temperature In degrees Celsius
%05.1f SOD Temperature In degrees Celsius
%05.1f DVE1 Temperature In degrees Celsius (when fitted)
%05.1f DVE2 Temperature In degrees Celsius (when fitted)
%03.2f 12V PSU A Supply In volts
%03.2f 12V PSU B Supply In volts
%03.2f 5V Supply In volts
%03.2f 3.3V Supply In volts
%03.2f 2.5V Supply In volts
%03.2f SID 1.8V Supply In volts
%03.2f 1.2V Supply In volts
%03.2f DVE 12V Supply In volts (when fitted)
%03.2f DVE 2.5V Supply In volts (when fitted)
%03.2f DVE 1.8V Supply In volts (when fitted)
%03.2f DVE 1.2V Supply In volts (when fitted)
%01x PSU A Status 1=OK, 0=failed
%01x PSU A Converted Status 1=OK, 0=failed
%01x PSU B Status 1=OK, 0=failed
%01x PSU B Converted Status 1=OK, 0=failed
%03.2f Fan 1 speed In RPM
%03.2f Fan 2 speed In RPM
%03.2f Fan 3 speed In RPM
%03.2f Fan 4 speed In RPM
%03.2f Fan 5 speed In RPM
The XV command is related to the enquire voltages command (X6).
Presmaster and IMM actually utilise X6 for sounding alarms, but XV should
then be used to find the real reasons for the alarm.