User manual

Automation Protocol Extended Status Commands
Miranda Technologies Ltd Page 146
Format Field Description
%c%c Cmd XN
%x Port Serial Port number
%x Protocol Current Protocol
Clean Feed XP
This command sets one of the auxiliary channels as the current clean feed
input, if supported.
CMD Param_1
XP %2x: Clean Feed
Possible settings for the Imagestore 300+ clean feed channel are as follows:
0x00: Program (factory default)
0x01: SDI A
0x02: SDI B
0x03: AB Mixer
0x04: AB Mixer + DVE
0x05: DSK 1
Possible settings for the Imagestore 750 clean feed channel are as follows:
0x00: Program (factory default)
0x01: SDI A
0x02: SDI B
0x03: SDI C
0x04: SDI D
0x05: Program AB Mixer
0x06: Program DVE output
0x07: Program DSK 1 output
0x08: Program DSK 2 output
0x09: Program DSK 3 output
Please note that for IS750 LOGO this command will be ineffective unless the
ISCF licence is enabled