User manual
Automation Protocol Extended Status Commands
Miranda Technologies Ltd Page 143
The highest four digits of the serial number define the product code, and the
lowest four digits define the unit ID. The exception is Imagestore 750 where
the four digit product code is followed by a zero then a three digit unit ID.
The full serial number for an Imagestore 750 can be obtained using the XU
command (see page 149).
Product codes are as follows:
0629: Imagestore 2
0675: Imagestore HD-TV
0730: Imagestore 3
0765: Imagestore 300
0781: Intuition SD
0811: Intuition HD
0814: Imagestore 300+ 1RU
0832: Imagestore 300+ 2RU
0838: Intuition+ SD
0839: Intuition+ HD
0872: Imagestore 750
0887: LGK-3901, DSK-3901
System Halt XL
This command requests a system halt as soon as the OS can process the
request.
CMD
XL
Example:
void SystemHalt()
{
remote_send(“XL”);
}
Input Mode XM
This command configures an input to pass SDI or a colour field and takes the
following format where the input parameter is system dependent as per the
table on page 47.
CMD Param_1 Param_2