User manual

Automation Protocol Extended Status Commands
Miranda Technologies Ltd Page 138
Time Code Source XE
This command sets the current Time Code source choosing between two
possible values, 0 = Linear Time Code (LTC) and 1 = Vertical Interrupt Time
Code (VITC).
CMD Param_1
XE %x: Source
Example:
void SetTimeCodeSource(int Source)
{
remote_send(“XE%x”, Source);
}
The command XE alternatively responds with information about the time
code source.
CMD
XE
For Imagestore 300[+], Imagestore HD-TV or Imagestore 750 the information
returned is
Format Field Description
%c%c Cmd XE
%x Source Time code source
0 = Linear Time Code (LTC)
1 = Vertical Interrupt Time Code (VITC).
For LGK-3901 or DSK-3901 the information returned is
Format Field Description
%c%c Cmd XE
%x Source Time code source
0 - Linear Time Code (LTC)
1 - Vertical Interrupt Time Code (VITC).
%d Valid Time code status
0 – Invalid
1 – Valid