User manual

Automation Protocol Extended Status Commands
Miranda Technologies Ltd Page 135
GPI Special X9
This command can perform two functions. One of the functions is to return a
status message containing a bit mask of the GPI input status. The other
function is to set the physical output status of a GPI.
CMD Param_1 Param_2
X9 %01x
0=Turn GPI off
1=Turn GPI on
2=Request Status
%02x
GPI number
(Not required for status request).
Note: For Imagestore 300[+] or Imagestore HD-TV units with GPI
lines on video and audio cards, the video GPIs are numbered 0
to 8 and the audio GPIs are numbered 9 to 17. For the
Imagestore IS750 only video GPIs are supported, numbered 0 to
15. For the LGK-3901 and DSK-3901only video GPIs 0 to 7 are
supported. Please check user manuals for details.
If a status request is sent the information returned is
Format Field Description
Cmd X9
%06x GPI Status Current GPI status
Enquire Extended Intuition Layer status XA
This command returns a status block about the layer status of the Imagestore
and Intuition. As the Imagestore can only control the first 14 layers of the
Intuition only the status of those layer are returned. The layer status of the
first two Imagestore layers is also included in the response for completeness.
Note that the Intuition layer status is based purely on the commands the
Imagestore has forwarded to the Intuition. This means if the Intuition is being
controlled directly either by automation or the front panel, the changes will
not be reflected in this command.
CMD
XA