The information returned on Imagestore 750 is:
Format Field Description
%c%c Cmd X6
%05.1f Ambient
Temperature
In degrees Celsius
%03.2f 12V PSU A
supply
1.00=OK, 0.00=Failed or not fitted
%03.2f 12V PSU B
supply
1.00=OK, 0.00=Failed or not fitted
%03.2f 12V supply In volts. Worst case measurement
%03.2f Video Voltage
Check
1.00=OK, 0.00=Failed. Checks all
video board voltages are within
tolerances
%03.2f DVE Voltage
Check
1.00=OK, 0.00=Failed. Checks all
DVE board voltages are within
tolerances
%03.2f 0.00 Unused field
%03.2f Fan Speed In RPM. Worst case fan 1-5 status
Voltage tolerances are +/-10% for the 12V supplies and +/-5% for all other
voltages.
Virtual GPI X7
Triggers the GPI macro associated with the GPI. It is called a virtual GPI
because it does not affect the physical GPI in any way. If it is required to set
the physical GPI use the X9 command.
CMD Param_1 Param_2
X7 %01x
On/Off
%02x
GPI Number
GPI Input Status X8
Note: For Imagestore 300[+] or Imagestore HD-TV units with GPI
lines on video and audio cards, the video GPIs are numbered 0
to 8 and the audio GPIs are numbered 9 to 17. For the
Imagestore IS750 only video GPIs are supported, numbered 0 to
15. For the LGK-3901 and DSK-3901only video GPIs 0 to 7 are
supported. Please check user manuals for details.