User manual
Automation Protocol Extended Status Commands
Miranda Technologies Ltd Page 132
%06x Fill 2 colour field RGB value
%01x Key 2 mode 1 = Colour field, 0 = Other
%06x Key 2 colour field RGB value
%01x C/Fill 3 mode 1 = Colour field, 0 = Other
%06x C/Fill 3 colour field RGB value
%01x D/Key 3 mode 1 = Colour field, 0 = Other
%06x D/Key 3 colour field RGB value
Enquire Voltages X6
Note: LGK-3901 and DSK-3901 do not support the X6 command.
This command returns information (separated by spaces) about the various
voltages on an Imagestore.
CMD
X6
The information returned on Imagestore 2, Imagestore 300 is:
Format Field Description
%c%c Cmd X6
%05.1f Temperature In degrees Celsius
%03.2f -12V supply
%03.2f -5V supply
%03.2f +3.3V supply
%03.2f +5V supply
%03.2f +5V Analogue supply
%03.2f +12V
%03.2f PLL Voltage
The information returned on Imagestore HD-TV is:
Format Field Description
%c%c Cmd X6
%05.1f Temperature In degrees Celsius
%03.2f -12V supply
%03.2f +1.8V supply
%03.2f +3.3V supply
%03.2f +5V supply
%03.2f +2.5V
%03.2f +12V
%03.2f 0.00 Unused field