User manual
Automation Protocol Squeezy Commands
Miranda Technologies Ltd Page 117
Run Squeeze Move W2
Runs a squeeze move to a particular preset position over a specified duration.
CMD Param_1 Param_2
W2 %02x : Sequence No. %03x : Duration
Sequence number:
Sequence Number Description
0x00 Play the currently loaded sequence in reverse
0x0x-0x61 (IS300/ISHD)
0x0x-0x63
Run the specified sequence number, 1 to 99
otherwise)
Duration:
When not specified or set as 0x001, the sequence will play out over the
default duration specified within the DVE Editor application.
When set between 0x002 and 0x3e6 (998 decimal) then the whole sequence
will be stretched to play within the duration specified.
If the duration is set as 0x3e7 (999 decimal) then the sequence will be loaded
without playing, and the first keyframe of the new sequence will be shown. If
the sequence number is 0x00 (i.e. play in reverse) then the last keyframe of
the currently loaded sequence will be shown instead.
For the Imagestore 2U/3, for which the Squeezy commands apply, the
duration is measured in frames for both interlaced and progressive standards.
Select Move Profile W3
Select linear or smooth velocity profile for squeeze moves.
CMD Param_1
W3 %01x: Profile : 0 = Linear, 1 = Smoothed