User manual
Installation Imagestore HDTV User Manual
Page 202 Miranda Technologies Ltd
REF 1 / 2
REF 1 HD Tri-level sync,
REF 2 SD analog sync, LTC or VITC.
Connector type: 75Ω BNC.
Connection of LTC or VITC
Where linear timecode is provided for Imagestore HDTV it should conform
to ANSI/SMPTE standard 12M-1995. The input level should be between one
and two volts peak-to-peak.
Mains Input
Imagestore HDTV can have up to 2
130W PSU’s fitted, each fed from its
own IEC connector.
The PSU’s are auto-ranging from
90-132V and 180-264V AC.
Each IEC connector is fused with a
2.5A anti-surge fuse.