User manual
Emergency Alert System Imagestore HDTV User Manual
Page 186 Miranda Technologies Ltd
Baud Rates
Baud rates are automatically set when the appropriate EAS unit is selected.
Load EAS (EAS On)
Setting EAS On will load the EAS message into memory. It will cut down the
DSK1 keyer if active and load the EAS template (as specified by the priority
of the stored message) and bring the crawl to air.
(The render time of the text will depend on the length of the string.
Maximum length = 2048 characters)
Unload EAS (EAS Off)
Setting EAS Off will remove the EAS crawl from air once it has completed. It
will cut down the crawl and restore the DSK 2 keyer to its original state.
EAS logs
All EAS transactions are recorded in the standard Imagestore HDTV log
files;
LOG{Serial number}.log and
LOG{Serial number}.old.
Access to the log file can be gained by copying it to a floppy disk. From the
front panel menu select Setup > File Operations > Diagnostics Save.
The file can then be viewed on a PC.