COM1 - COM4
For serial comms RJ45 connectors are provided, software-selectable as
RS422 or RS232.
Pin No. Signal Name RS422 Signal Name RS232
1 TX+ RTS
2 TX- TXD
3 RX+ CTS
4 NC NC
5 NC NC
6 RX- RXD
7 NC NC
8 GND GND
Connector type: 8 pin RJ45.