User manual

Oxtel RCP Operation Imagestore User Manual
Page 90 Miranda Technologies Ltd
either the file name or the image title. The 2
nd
from left soft key toggles
between "File" and "Title" to determine which is to be used for searching.
The rotary control associated with "Letter" is a coarse control quickly
scrolling through the library images displaying the first file, or title, starting
with each alphanumeric character. Once the starting character has been
located the rotary control under "File" may be used as a fine control to step
forwards or backwards through each file or title from that point. The rotary
control associated with "Cursor" may be used to move the cursor through a
file name or title and the keypad may be used to amend any character.
Once the required image is indicated on the display, pressing the ENTER key
will cause it to load into the preview keyer.
Loading a Live Image
To load the layer image at the Fill and Key video inputs directly to the
programme output, press the left-hand soft key, identified on the display as
"Live". The video input will then be passed directly to the either the FG or
MG keyer and appear on the PGM output. The display will indicate "Live
Loaded".
To cancel or override the "live load" condition, select an image from the
Imagestore library and load it. The action of loading a new image to the
keyer will cancel the "live" condition.
Saving Images
The procedure for saving images from either the foreground or midground
stores in Cascade mode is identical to that for Swap-PVW mode and
reference should be made to that description.
Editing Images
Images can only be edited in Cascade mode when the midground keyer is not
"on-air". Ensure that there will be no requirement for the midground image to
be taken "on-air" during an editing session.
When using the Cascade mode editing features refer to the "editing images"
section of RCP Swap-PVW Mode given in earlier paragraphs of this guide.