purpose. When a purpose is to be allocated to any "pot" a legend will appear
on the LCD directly below the "pot" indicating its current purpose.
Swap/Preview Mode Operations
The RCP can be used in either of the two operational modes to control image
loading, image editing, image previewing, image saving and image
transmission. The features and facilities available differ significantly
dependent on the operational mode. This user guide describes both modes
separately and some duplication may occur.
In all circumstances pressing the ESC button repeatedly until it is no longer
illuminated returns the controller to its start up display.
Transmission Control
The group of buttons in the bottom, right-hand corner of the controller is used
to take images on and off air and to exchange images between the program
and preview keyers. The use of these buttons does not involve any prompts
on the controller LCD.
Note The SWAP button is used to determine the action of the TAKE
button and pressing it will cause the legend above the SWAP button
to either illuminate or extinguish.
Program Fade to Black
Pressing the "Fade to Black" button will cause the programme output to fade
to black over the number of frames set for that transition.
When the output has been faded to black the button becomes illuminated.
Pressing the button again will cause the normal program output to reappear
over the same number of frames and the button light will go out.
The FTB option may be disabled where appropriate and the Miranda
Technologies Ltd helpdesk will provide details on request.