Instruction manual

GUIDE TO INSTALLATION AND OPERATION
56 | DAP-1781
4.13 Rear Type
This tab shows the type of the rear panel: single or
dual width, and digital inputs/outputs standard.
The 2 RU dual width rear panels and the 3 RU
single width panels allow the installation of any
optional Dolby module, either encoder or decoder.
The 2 RU single width rear panels are specialized
for one type of an optional Dolby module.
4.14 Factory / Presets
4.14.1 Factory
The Factory profile is a read-only set of factory-
selected values that can be used to return the DAP-
1781 to a standard operating condition without
affecting the User Presets.
The DAP-1781 Menu in section 3.2 indicates
the default values for all parameters.
Card parameters and card alarms can be
reset to their default values separately.
The Generator Metadata parameters are
included in the Factory Preset.
4.14.2 User Presets
The five User Presets are read-write data registers
that allow you to save the contents of the Current
state of the DAP-1781 for later recall.
Select any one of the five presets using the pull-
down list. The name of the currently-selected User
Preset is shown on the name bar.
The Generator Metadata parameters are included in
the User Presets. Refer to Metadata - Control tab
.
Click Load to load the contents of the selected
User Preset into the DAP-1781. All parameter
settings and values will be replaced by the
contents of the selected User Preset.
Click Save to store the current parameter
settings and values from the DAP-1781 into
the selected User Preset. The existing
contents of the preset will be overwritten.
4.14.3 GPI
The five GPI inputs can be provided only by a video
processor card through the A-BUS link. When a
contact closure to ground is present, the State will
turn to green and, if Enable is checked, the GPI
inputs 1 to 5 will perform a Load User Presets
User1 to User5.