SDS

MSC-002 - Liquid Poultice Part A
Revision Date: 27-Jun-2013
_____________________________________________________________________________________________
_____________________________________________________________________________________________
Page 3 / 7
6. ACCIDENTAL RELEASE MEASURES
Personal precautions, protective equipment and emergency procedures
Personal Precautions
Use personal protection recommended in Section 8.
Environmental precautions
Environmental precautions
See Section 12 for additional Ecological Information. See Section 13: DISPOSAL
CONSIDERATIONS.
Methods and material for containment and cleaning up
Methods for Containment
Prevent further leakage or spillage if safe to do so.
Methods for Clean-Up
Absorb with inert material and then place in suitable container for chemical waste.
7. HANDLING AND STORAGE
Precautions for safe handling
Advice on Safe Handling
Handle in accordance with good industrial hygiene and safety practice. Use personal
protection recommended in Section 8. Wash thoroughly after handling before eating,
drinking, smoking, or using toilet facilities. Do not mix with other chemicals. Use in
accordance with product label instructions. Use common sense and care around chemicals.
Consult your supervisor for all other hygienic and safety precautions.
Conditions for safe storage, including any incompatibilities
Storage Conditions
Keep container tightly closed and store in a cool, dry and well-ventilated place. Protect from
sunlight. Do not store at temperatures below 0°C (32°F) or above 43°C (110°F). Keep out
of the reach of children.
Incompatible Materials
None known based on information supplied.
8. EXPOSURE CONTROLS/PERSONAL PROTECTION
Exposure Guidelines
Chemical Name
ACGIH TLV
OSHA PEL
NIOSH IDLH
Proprietary
STEL: 6 ppm
TWA: 3 ppm
TWA: 3 ppm
TWA: 6 mg/m
3
(vacated) TWA: 3 ppm
(vacated) TWA: 8 mg/m
3
(vacated) STEL: 6 ppm
(vacated) STEL: 15 mg/m
3
IDLH: 30 ppm
TWA: 3 ppm
TWA: 8 mg/m
3
STEL: 6 ppm
STEL: 15 mg/m
3
Proprietary
TWA: 20 ppm
TWA: 50 ppm
TWA: 240 mg/m
3
(vacated) TWA: 25 ppm
(vacated) TWA: 120 mg/m
3
(vacated) S*
S*
IDLH: 700 ppm
TWA: 5 ppm
TWA: 24 mg/m
3
Appropriate engineering controls
Engineering Controls
Apply technical measures to comply with the occupational exposure limits. Eyewash
stations. Showers.