SDS

Page 4 / 9
MSC-048 - Grout Release
Revision Date: 29-Jan-2016
Environmental precautions
Environmental precautions Prevent from entering into soil, ditches, sewers, waterways and/or groundwater. See
Section 12, Ecological Information. See Section 13: DISPOSAL CONSIDERATIONS.
Methods and material for containment and cleaning up
Methods for Containment Prevent further leakage or spillage if safe to do so.
Methods for Clean-Up Steps to be taken in case material is released or spilled: wipe, scrape or soak up in an inert
material and put in a container for disposal.
Precautions for safe handling
Advice on Safe Handling Handle in accordance with good industrial hygiene and safety practice. Avoid contact with
skin, eyes or clothing. Use personal protection recommended in Section 8. Obtain special
instructions before use. Do not handle until all safety precautions have been read and
understood. Avoid breathing vapors or mists. Use only outdoors or in a well-ventilated area.
Keep away from heat/sparks/open flames/hot surfaces. No smoking. Ground/bond
container and receiving equipment. Use non-sparking hand tools and explosion-proof
electrical equipment. Take precautionary measures against static discharges. Follow all
product label instructions. Use only as directed.
Conditions for safe storage, including any incompatibilities
Storage Conditions Keep container tightly closed and store in a cool, dry and well-ventilated place. Store locked
up. Precautions to be taken in handling and storing: use a ground strap. Store upright in a
cool place below 77° F (25° C). Keep out of the reach of children.
Incompatible Materials Incompatible with oxidizing agents.
Exposure Guidelines
Chemical Name
ACGIH TLV
OSHA PEL
NIOSH IDLH
Proprietary Solvent
TWA: 100 ppm
TWA: 500 ppm
TWA: 2900 mg/m
3
(vacated) TWA: 100 ppm
(vacated) TWA: 525 mg/m
3
IDLH: 20000 mg/m
3
Ceiling: 1800 mg/m
3
15 min
TWA: 350 mg/m
3
Proprietary
TWA: 400 ppm
TWA: 400 ppm
TWA: 1400 mg/m
3
(vacated) TWA: 400 ppm
(vacated) TWA: 1400 mg/m
3
IDLH: 2000 ppm
TWA: 400 ppm
TWA: 1400 mg/m
3
Proprietary solvent
STEL: 500 ppm
TWA: 400 ppm
TWA: 500 ppm
TWA: 2000 mg/m
3
(vacated) TWA: 400 ppm
(vacated) TWA: 1600 mg/m
3
(vacated) STEL: 500 ppm
(vacated) STEL: 2000 mg/m
3
IDLH: 750 ppm
Ceiling: 440 ppm 15 min
Ceiling: 1800 mg/m
3
15 min
TWA: 85 ppm
TWA: 350 mg/m
3
Proprietary acetate
STEL: 200 ppm
TWA: 150 ppm
TWA: 150 ppm
TWA: 710 mg/m
3
(vacated) TWA: 150 ppm
(vacated) TWA: 710 mg/m
3
(vacated) STEL: 200 ppm
(vacated) STEL: 950 mg/m
3
IDLH: 1700 ppm
TWA: 150 ppm
TWA: 710 mg/m
3
STEL: 200 ppm
STEL: 950 mg/m
3
Appropriate engineering controls
Engineering Controls Apply technical measures to comply with the occupational exposure limits. Ensure
adequate ventilation, especially in confined areas. Eyewash stations. Showers. Prevent
build-up of vapors by opening all doors and windows to achieve cross-ventilation.
7. HANDLING AND STORAGE