COMMISSIONING
Maximum Temperature Setting
Before using the shower the maximum temperature
must be checked to make sure that it is at a safe
level. It has been preset to approximately 41°C at
the factory but due to variations in site conditions
the maximum temperature may need adjustment.
Note! Make sure that the hot water temperature
is at least 55°C and that there is sufcient supply.
For Type 2 installations the maximum blend
temperature is determined by the application,
refer to the TMV2 Requirements Manual.
1. Turn on the mixer to the maximum temperature
and maximum ow (i.e. fully anticlockwise) and
allow the temperature to stabilise.
If the temperature is too hot or too cold adjust
as follows:
2. Carefully remove the concealing cap from the
control knob.
3. Loosen the control lever grubscrew with the
2.5 mm hexagonal key (supplied) and pull off
the control lever.
4. If applicable unscrew the hub retaining screw
with a 2.5 mm hexagonal key.
Note! Do not remove the hub.
Control Lever
Hub
Hub Retaining
Screw
Grubscrew
+
-
+
-
Concealing Cap
2.5 mm Hexagonal Key
Flow Control
Lever
Or
5. Insert the 2.5 mm hexagonal key into the
centre of the spindle and engage with the
recessed temperature adjusting screw.
6. Rotate the hexagonal key until the required
maximum temperature is obtained at the
shower. Anticlockwise to increase the
temperature, or clockwise to decrease the
temperature (¼ turn = approximately 1°C).
7. Once the desired maximum blend temperature
has been achieved turn off the mixer by
rotating either the hub or ow control lever
(depending on model) fully clockwise.
Note! Do not remove the hub.
8. If applicable ret the hub retaining screw.
9. Ret the control lever with the lever at the top
and retighten the grubscrew.
10. Check that the shower temperature is correct.