SHOWER FITTINGS Installation & User Guide THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER 1
Contents Section 1 ..... Introduction Page ................................................................... 3 2 ..... Important Safety Information ........................................... 4 3 ..... Pack Contents Checklist .................................................. 5 4 ..... Dimensions ................................................................... 7 5 ..... Specifications ................................................................... 8 6 ..... Installation Requirements .........
Section 1 Introduction Thank you for purchasing a quality product. To enjoy the full potential of your new product, please take time to read this guide thoroughly, having done so, keep it handy for future reference. Mira shower fittings are precision engineered to give a satisfactory shower over a range of pressures. The fittings are suitable for pressures up to 5.0 bar and pressures down to 0.05 bar.
Section 2 Important Safety Information 1. WARNING! Products manufactured by us are safe and without risk provided they are installed, used and maintained in good working order in accordance with our instructions and recommendations. 2. Caution! 2.1. Read all of these instructions. 2.2. Retain this guide for later use. 2.3. Pass on this guide in the event of change of ownership of the installation site. 2.4. Follow all warnings, cautions and instructions contained in this guide. 2.5.
Section 3 Pack Contents Checklist 9Tick the appropriate boxes to familiarise yourself with the part names and to confirm that the parts are included.
Section Pack Contents Checklist 3 9Tick the appropriate boxes to familiarise yourself with the part names and to confirm that the parts are included.
Section Dimensions 4 600 645 75.
Section Specifications 5 Minimum maintained pressure: 0.05 bar. Maximum maintained pressure: 5.0 bar. Warning! Exceeding the stated maximum maintained pressure could result in excessive spray forces and possible damage to the handset. Pressure loss = Pressure difference between the inlet and outlet of the fitting. Mira Discovery adjustable range flow rates - Low capacity nozzle rings fitted 22 Start Flow Rate (litres/minute) 20 Soothe 18 Eco 16 14 12 Force 10 8 6 4 2 0 0 0.2 0.4 0.6 0.
Section 6 Installation Requirements 1. Plumbing Read the section “Important Safety Information” first. 1.1. Supply pipework MUST be flushed to clear debris before connecting the appliance. 1.2. A hose retaining ring is supplied to prevent the handset from dropping below the spill-over level of the bath or shower, which could lead to contamination from back siphonage.
Section 7 Installation 1. Mira Discovery ev - Exposed Variable Shower Fittings Solid, dry-lined, stud partition, shower cubicle or laminated panel walls Read the section “Installation Requirements” first. The slide bar should be fixed to the wall to one side of the product and at a convenient height for all the family. It should be positioned so that it discharges down the centre line of the bath, or across the opening of a shower cubicle and should be directed away from the shower control.
1.3. For solid walls drill two 8.0 mm diameter holes at 600 mm centres and insert the wall plugs. Screw Bracket Bracket Cover Slide Bar Note! Special consideration should be given to the fixing arrangements when installing on to a dry lined, stud partition, shower cubicle or laminated panel wall structures. Installers may wish to obtain alternative proprietary cavity fixing, or choose other options, however, these methods of fixing are beyond the scope of this guide. 1.4.
2. Mira Discovery biv - Built-in Right Angle Connector (RAC) Read the section “Installation Requirements” first. The right angled connector assembly (RAC) for use with built-in shower controls, should be positioned above and offset from the top outlet of the shower control. This will prevent the flexible hose from obstructing the temperature and flow controls used to operate the shower. The pipework between the shower control and the RAC fitting is not supplied as part of the product. Outlet Pipe (15mm) 2.
2.7. Drill the two RAC wallplate fixing holes, if necessary make a recess approximately 6 mm deep to accept the RAC wallplate. Plug the two fixing holes. Foam Seal 2.8. Fix the RAC wallplate to the wall with the two fixing screws. Backplate Nut Olive 2.9. Temporarily fit the two fixing screws to the RAC wallplate. This will prevent the holes from becoming blocked with plaster and grout. Copper Pipe 2.10. Finish the surface of the wall as required ensuring the pipework is protruding by at least 20mm. 2.
3. Mira Discovery bir - Built-in Rigid Shower Fittings Solid, dry-lined, stud partition, shower cubicle or laminated panel walls Read the section “Installation Requirements” first. The bir spray head should be positioned at a convenient height for all the family. It should be positioned so that it discharges down the centre line of the bath, or across the opening of the shower cubicle and it should be directed away from the shower control. 3.1. 3.2. 3.3. 3.4.
Section 8 Operation 1. Spray action The handset spray head has four different spray actions:- start, combination, calm, combination and blast setting. The handset operation is described below. 1. Eco To access the eco setting, turn the spray plate fully clockwise. Water will flow from the outer set of holes and the flow rate will be reduced. 2. Start To access the start setting turn the spray plate anticlockwise until it 'clicks' (one click from the eco setting).
2. Height and direction adjustment Locking Wheel Clamp Bracket Assembly Section 9 Maintenance 1. Cleaning Many household cleaners contain abrasives and chemical substances, and should not be used for cleaning plated or plastic fittings. These finishes should be cleaned with a mild washing up detergent or soap solution, and then wiped dry using a soft cloth. Handset spray plate - external 1.1.
Section 10 Fault Diagnosis Read the section “Important Safety Information” first. Provided that the shower fitting has been correctly installed and is operated in accordance with the instructions contained in this guide, difficulties should not arise. If any maintenance is required then it must be carried out by a competent tradesperson for whom the fault diagnosis chart and maintenance instructions are provided.
Section Spare Parts 11 1. Adjustable Fittings Spare parts list 1595.030 1595.034 1595.033 1595.077 150.58 1595.074 1595.073 632.73 1595.035 450.20 1595.031 1595.032 1595.071 Handset Slide Bar Support Assembly (components marked 'A') Clamp Bracket Assembly Screw Pack (components marked 'B') Hose Slide Bar Hose Retainer Hose Washer Right Angle Connector (RAC) Shroud RAC Mounting Pack Adjuster Ring Spray Plate Pack LC Flow Regulator 2. Rigid Fittings Spare parts list 1595.075 1595.076 1595.
Adjustable Fittings Spare parts diagram B 632.73 A A 1595.033 1595.074 1595.030 1595.032 450.20 1595.031 632.73 B 1595.071 A 150.58 1595.035 1595.
Customer Service Guarantee of Quality Spare Parts Mira Showers guarantee your product against any defect in materials or workmanship for the period shown in the Guarantee Registration Document included with your shower. We maintain an extensive stock of spares, and aim to have functional parts available for ten years from the date of final manufacture of the product. Alternatively, to confirm the applicable guarantee period please contact Customer Services.