Mira Discovery SHOWER FITTINGS Installation & User Guide These instructions are to be left with the user
Contents Introduction.............................................................................................. 3 Important Safety Information.................................................................. 4 Pack Contents Checklist......................................................................... 5 Dimensions............................................................................................... 7 Specifications............................................................................
Introduction Thank you for purchasing a quality product. To enjoy the full potential of your new product, please take time to read this guide thoroughly, having done so, keep it handy for future reference. Mira shower fittings are precision engineered to give a satisfactory shower over a range of pressures. The fittings are suitable for pressures up to 5.0 bar and pressures down to 0.05 bar.
Important Safety Information 1. Warning! 1.1 Products manufactured by us are safe and without risk provided they are installed, used and maintained in good working order in accordance with our instructions and recommendations. 2. Caution! 2.1 Read all of these instructions. 2.2 Retain this guide for later use. 2.3 Pass on this guide in the event of change of ownership of the installation site. 2.4 Follow all warnings, cautions and instructions contained in this guide. 2.
Pack Contents Checklist Tick the appropriate boxes to familiarize yourself with the part names and to confirm that the parts are included.
BIV - Built-In Variable Right Angle Connector Fittings Pack 1 x Wallplate 1 x Backplate 1 x Olive 2 x 'O' Seals 2 x Wall Plug 1 x Elbow 1 x Shroud 2 x Wallplate Screws 1 x Backplate Nut 2 x Backplate Screws BIR - Built-In Rigid Arm and Shower Head Fittings Pack 2 x Wall Plugs 2 x Fixing Screws 1 x Threaded Connector 1 x Shower Arm 1 x Rubber Washer 1 x Cover Trim 1 x Spray Head
Dimensions 645 600 75.
Specifications Minimum maintained pressure: 0.05 bar. Maximum maintained pressure: 5.0 bar. Warning! Exceeding the stated maximum maintained pressure could result in excessive spray forces and possible damage to the handset. Pressure loss = Pressure difference between the inlet and outlet of the fitting. Mira Discovery adjustable range flow rates - Low capacity nozzle rings fitted 22 Start Flow Rate (litres/minute) 20 Soothe 18 Eco 16 14 12 Force 10 8 6 4 2 0 0 0.2 0.4 0.8 0.
Installation Requirements 1. Plumbing Read the section “Important Safety Information” first. 1.1 Supply pipework MUST be flushed to clear debris before connecting the appliance. 1.2 A hose retaining ring is supplied to prevent the handset from dropping below the spill-over level of the bath or shower, which could lead to contamination from back siphonage. The supplied hose retaining ring should meet the great majority of user requirements for shower installations with flexible outlet fittings.
Installation 1. Mira Discovery ev - Exposed Variable Shower Fittings Solid, dry-lined, stud partition, shower cubicle or laminated panel walls Read the section “Installation Requirements” first. The slide bar should be fixed to the wall to one side of the product and at a convenient height for all the family. It should be positioned so that it discharges down the centre line of the bath, or across the opening of a shower cubicle and should be directed away from the shower control.
1.3 For solid walls drill two 8.0 mm diameter holes at 600 mm centres and insert the wall plugs. Note! Special consideration should be given to the fixing arrangements when installing on to a dry lined, stud partition, shower cubicle or laminated panel wall structures. Installers may wish to obtain alternative proprietary cavity fixing, or choose other options, however, these methods of fixing are beyond the scope of this guide. Screw Bracket Bracket Cover 1.
2. Mira Discovery biv - Built-in Right Angle Connector (RAC) Read the section “Installation Requirements” first. The right angled connector assembly (RAC) for use with built-in shower controls, should be positioned above and offset from the top outlet of the shower control. This will prevent the flexible hose from obstructing the temperature and flow controls used to operate the shower. The pipework between the shower control and the RAC fitting is not supplied as part of the product. Outlet Pipe (15 mm) 2.
2.7 Drill the two RAC wallplate fixing holes, if necessary make a recess approximately 6 mm deep to accept the RAC wallplate. Plug the two fixing holes. Foam Seal 2.8 Fix the RAC wallplate to the wall with the two fixing screws. 2.9 Temporarily fit the two fixing screws to the RAC wallplate. This will prevent the holes from becoming blocked with plaster and grout. 2.10 Finish the surface of the wall as required ensuring the pipework is protruding by at least 20 mm. Backplate Nut Olive Copper Pipe 2.
3. Mira Discovery bir - Built-in Rigid Shower Fittings Solid, dry-lined, stud partition, shower cubicle or laminated panel walls Read the section “Installation Requirements” first. The bir spray head should be positioned at a convenient height for all the family. It should be positioned so that it discharges down the centre line of the bath, or across the opening of the shower cubicle and it should be directed away from the shower control. 3.
Operation 1. Spray Action The handset spray head has four different spray actions; Eco, Start, Soothe and Force. The handset operation is described below. 1. Eco To access the eco setting, turn the spray plate fully clockwise. Water will flow from the outer set of holes and the flow rate will be reduced. 2. Start To access the start setting turn the spray plate anticlockwise until it 'clicks' (one click from the eco setting). Water will flow from the outer set of holes. 3.
2. Height and direction adjustment Locking Wheel Clamp Bracket Assembly Maintenance Cleaning Many household cleaners contain abrasives and chemical substances, and should not be used for cleaning plated or plastic fittings. These finishes should be cleaned with a mild washing up detergent or soap solution, and then wiped dry using a soft cloth. Handset spray plate - external Use your thumb or a soft cloth to wipe any limescale from the soft nozzles and the front surface of the handset spray plate.
Fault Diagnosis Read the section “Important Safety Information” first. Provided that the shower fitting has been correctly installed and is operated in accordance with the instructions contained in this guide, difficulties should not arise. If any maintenance is required then it must be carried out by a competent tradesperson for whom the fault diagnosis chart and maintenance instructions are provided. Before replacing any parts ensure that the underlying cause of the malfunction has been identified.
Spare Parts Adjustable Fittings 150.58 Hose 450.20 RAC Mounting Pack 632.73 Hose Washer 1595.030 Handset 1595.031 Adjuster Ring 1595.032 Spray Plate Pack LC 1595.033 Clamp Bracket Assembly 1595.034 Slide Bar Support Assembly (components marked 'A') 1595.035 Right Angle Connector (RAC) Shroud 1595.071 Flow Regulator 1595.073 Hose Retainer 1595.074 Slide Bar 1595.077 Screw Pack (components marked 'B') Rigid Fittings 1595.075 BIR Head 1595.076 Concealing Trim 1595.071 Flow Regulator 1595.
B 632.73 A A 1595.033 1595.074 1595.030 1595.032 450.20 1595.031 632.73 B 1595.071 A 150.58 1595.035 1595.
Customer Service 1075741-W2-A 20 © Kohler Mira Limited, March 2007