User Manual Part 2
17
18
SET OFF
SET ON
RF RF
AF AF
BT BT
RF
AF
BT
5
LIMIT
MODE
ON
OFF
SET
SET 10dB
RF RF
AF AF
BT BT
RF
AF
BT
5
AF--SEN
MODE
0 DB
SET
10 DB
SET
20 DB
SET
30 DB
SET
0 DB 10 DB 20 DB 30 DB
ENCRYP
MODE
ON
OFF
DIGITAL WIRELESS BODY PACK TRANSMITTER
DIGITAL WIRELESS BODY PACK TRANSMITTER
(4) AF-SEN: Setup and Change of Input Sensitivity
A. Operate via MODE Button
B. Operation Guide:
a. Press "MODE" and stop on "AF-SEN" function, the display showing current state
will be flashing and is ready to be modified.
b. Every push of ''SET'' button, the dB value increases by 10dB to a maximum of
30dB.
**NOTE:
1. The higher the gains are set, the lower the dynamic range for signal input.
Meanwhile the danger of unwanted noises and feedback getting into the system would
obviously rise.
2. It is advisable to set the sensitivity level at 0dB when using electric guitar.
3. When set at 0 dB, the maximum input level without causing distortion to the
transmitter is 1 Vrms (0 dBv). Hence, please make sure the input signal does not
exceed 1 Vrms. SPL for handheld microphone is 145dB.
(5) LIMIT: Setup and Change of Input Limit
A. Operate via MODE Button
B. Operation Guide:
a. Press "MODE" and stop on "LIMIT" function, the display showing current state will
be flashing and is ready to be modified.
b. Press ''SET'' to change the setting to "ON" or "OFF".
**NOTE: When the LIMIT is ''ON'', the maximum output of the receiver is limited to 1V.
(6) ENCRYP: Displays Information of Encryption
A. Operate via MODE Button
B. Operation Guide:
a. Press "MODE" and stop on "ENCRYP" function, the display showing current state
will be flashing.
**NOTE: "ENCRYP" function is added to display status information only. Changing of
current status must be done from receiver via ACT.