Section 4. First aid measures
Protection of first-aiders
:
No action shall be taken involving any personal risk or without suitable training. If it is
suspected that fumes are still present, the rescuer should wear an appropriate mask or
self-contained breathing apparatus. It may be dangerous to the person providing aid to
give mouth-to-mouth resuscitation.
See toxicological information (Section 11)
Section 5. Fire-fighting measures
Promptly isolate the scene by removing all persons from the vicinity of the incident if
there is a fire. No action shall be taken involving any personal risk or without suitable
training. Move containers from fire area if this can be done without risk. Use water
spray to keep fire-exposed containers cool.
Hazardous thermal
decomposition products
Specific hazards arising
from the chemical
Decomposition products may include the following materials:
carbon dioxide
carbon monoxide
Flammable solid.
Fire-fighters should wear appropriate protective equipment and self-contained breathing
apparatus (SCBA) with a full face-piece operated in positive pressure mode.
Special protective
equipment for fire-fighters
Use dry chemical,
CO₂,
water spray (fog) or foam.
Extinguishing media
:
:
:
Do not use water jet.
Suitable extinguishing
media
:
Unsuitable extinguishing
media
:
Special protective actions
for fire-fighters
:
Section 6. Accidental release measures
Environmental precautions
Personal precautions, protective equipment and emergency procedures
:
:
No action shall be taken involving any personal risk or without suitable training.
Evacuate surrounding areas. Keep unnecessary and unprotected personnel from
entering. Do not touch or walk through spilled material. Shut off all ignition sources.
No flares, smoking or flames in hazard area. Provide adequate ventilation. Wear
appropriate respirator when ventilation is inadequate. Put on appropriate personal
protective equipment.
Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains
and sewers. Inform the relevant authorities if the product has caused environmental
pollution (sewers, waterways, soil or air).
Move containers from spill area. Use spark-proof tools and explosion-proof equipment.
Avoid dust generation. Do not dry sweep. Vacuum dust with equipment fitted with a
HEPA filter and place in a closed, labeled waste container. Place spilled material in a
designated, labeled waste container. Dispose of via a licensed waste disposal
contractor.
Small spill
:
Methods and materials for containment and cleaning up
For non-emergency
personnel
For emergency responders
:
If specialised clothing is required to deal with the spillage, take note of any information in
Section 8 on suitable and unsuitable materials. See also the information in "For non-
emergency personnel".
Date of issue/Date of revision
:
4/6/2015.
Date of previous issue
:
No previous validation.
Version
:
1