Safety Data Sheets (SDS)
Section 4. First aid measures
Protection of first-aiders
:
No action shall be taken involving any personal risk or without suitable training. If it is
suspected that fumes are still present, the rescuer should wear an appropriate mask or
self-contained breathing apparatus. It may be dangerous to the person providing aid to
give mouth-to-mouth resuscitation.
Notes to physician
:
Treat symptomatically. Contact poison treatment specialist immediately if large
quantities have been ingested or inhaled.
Specific treatments
:
No specific treatment.
Can cause central nervous system (CNS) depression. May be fatal if swallowed and
enters airways.
:
Ingestion
Over-exposure signs/symptoms
Skin contact
Ingestion
Inhalation
Adverse symptoms may include the following:
respiratory tract irritation
coughing
nausea or vomiting
headache
drowsiness/fatigue
dizziness/vertigo
unconsciousness
Adverse symptoms may include the following:
nausea or vomiting
No specific data.
:
:
:
Eye contact
:
No specific data.
See toxicological information (Section 11)
Indication of immediate medical attention and special treatment needed, if necessary
Section 5. Fire-fighting measures
Promptly isolate the scene by removing all persons from the vicinity of the incident if
there is a fire. No action shall be taken involving any personal risk or without suitable
training. Move containers from fire area if this can be done without risk. Use water
spray to keep fire-exposed containers cool.
Hazardous thermal
decomposition products
Specific hazards arising
from the chemical
Decomposition products may include the following materials:
carbon dioxide
carbon monoxide
Flammable liquid and vapor. Runoff to sewer may create fire or explosion hazard. In a
fire or if heated, a pressure increase will occur and the container may burst, with the risk
of a subsequent explosion. The vapor/gas is heavier than air and will spread along the
ground. Vapors may accumulate in low or confined areas or travel a considerable
distance to a source of ignition and flash back.
Fire-fighters should wear appropriate protective equipment and self-contained breathing
apparatus (SCBA) with a full face-piece operated in positive pressure mode.
Special protective
equipment for fire-fighters
Use dry chemical,
CO₂,
water spray (fog) or foam.
Extinguishing media
:
:
:
Do not use water jet.
Suitable extinguishing
media
:
Unsuitable extinguishing
media
:
Special protective actions
for fire-fighters
:
Date of issue/Date of revision
:
3/11/2020
Date of previous issue
:
3/4/2020
Version
:
18.02
4/18
2750
MINWAX® WOOD FINISH®
Jacobean