User`s manual

SNMP-SSL
69
Appendix C Technical Information
Specification
CPU 16-bits AC1105 Fast Ethernet RISC Processor Phoenix Kernel
Memory 2MB (1Mbit x16) TFBGA Flash ROM
2MB (1Mbit x16) SDRAM
Serial
Communication
Two UART Channels, one RJ-45, one Gold finger.
LAN Controller 10/100 Mbits Ethernet controller
Network Connection 10/100 TX RJ-45 jack connector
RTC Real time clock
Network Protocol SNMP over UDP/IP
HTTP over TCP/IP
ARP, TFTP, SSH, SSL, NTP and ICMP
Supported MIB UPS MIB (RFC1628)
SNMP-SSL MIB
Operating
Temperature
0 ~ 40° C
Operating Humidity 10 ~ 80 %
Power Input 8-15V DC
Power Consumption 3.0 Watts Maximum
Size (L x W x H) 5.1 x 2.4 x 0.7 inches
130 x 60 x 18.2 mm
Weight 0.2 lbs
0.09 Kgs
Regulatory
compliance
FCC class B
CE class B
Dipswitch Definition
No. SW1 SW2 Function Mode
1 ON ON Factory Diagnostic Mode
2 ON OFF
Serial upgrade mode
3 OFF ON Reserved
4 OFF OFF Operating Mode
LED Definition
No. Port Green LED Amber LED Function
1 Flashing (1sec) OFF Ethernet 100M Traffic
2 OFF Flashing (1sec) Ethernet 10M Traffic
3
Network
OFF OFF Ethernet disconnect
4 ON Flashing (1~3sec) RS-232 Port Active
5 OFF Flashing (1sec) Serial Upgrade Mode
6
Two LEDs cross
Flashing
Two LED cross
Flashing
Auto Diagnostic Mode
7
COM
ON ON Hardware Error