SNMP Accessories For Minuteman UPSs
Select Minuteman UPS products are capable of accepting Simple
Network Management Protocol (SNMP) communications cards. SNMP is a
communications protocol for devices to a Local Area Network (LAN). It can
be used to obtain the status of a UPS connected to the network and issue
commands to it.
SNMP Capable UPSs
Minuteman UPS product lines which offer optional SNMP communi-
cations capability include:
• Endeavor 6 & 10kVA tower
• Endeavor 6kVA rack
• Endeavor 1-3kVA rack/tower
• CPE 1-3kVA
• EnterprisePlus 750VA-3kVA
• PRO-RT 1000-1500VA
Features
SNMP option cards provide IT/Network administrators with a compre-
hensive set of features to manage and monitor UPSs over the LAN:
• Connect the UPS directly to a LAN - utilizing a standard RJ45
Ethernet connection; requires no special application software
• Network UPS management - monitor and manage the UPS over
any computer attached to the network
• Integrate UPS into Network Management System (NMS) - using
the inlcluded MIB (Management Information Base) agent or the
included SNMP management software
• Schedule events - shutdown or restart connected equipment daily,
weekly, or monthly using the integrated scheduler
• Track utility problems via Event Logs - to provide history of power
events on the UPS including: power quality, equipment draw, and
blackouts.
• Multiple server shutdown - using the included SNMP management
software allows the UPS to shutdown multiple devices sequentially
when a power event occurs
• Event Notifi cation - notify multiple IT personnel via SNMP traps or
e-mail when a power event occurs
• Telnet Support - for fl exible confi guration of the SNMP card
Card Installation
All compatible Minuteman UPSs feature an SNMP option slot at the
rear of the unit.
Browser-based Management Cards
Multiple options are available to meet the needs of a variety of network
requirements. Cards include:
SNMP-NV6 NEW!
IPv4/IPv6 compliant; compatible with Endeavor
1-3kVA, Endeavor 6&10kVA,
EnterprisePlus, & PRO-RT UPSs. New features
include:
• Full compatibility with both IPv4 and IPv6 standards making it the
perfect card for future migration options
• Compatible with SNMPv1, v2C, and v3 protocols
• Supports SYSLOG; send messages to a maximum of four Syslog
servers when an event occurs
• Supports RADIUS Login application
• User Confi gurable Event Alarm levels
• Adjustable Low Battery warning alarm
• Batch Confi gurations and Upgrades
SNMP-NET
Base SNMP card compatible with Endeavor
1-3kVA, Endeavor 6&10kVA, EnterprisePlus, &
PRO-RT UPSs
SNMP-SSL
SNMP-NET card with SSL security features
compatible with Endeavor 1-3kVA, Endeavor
6&10kVA,
EnterprisePlus, & PRO-RT UPSs. Security Features
include:
• Supports SSL, SSH, HTTPs, and SNMPv3 security protocols
• Supports RADIUS Login Application
NetAgent SNMP
SNMP management compatible with CPE Series UPSs.
Monitoring Accessories
Multiple accessories are available to provide administrators with a
complete monitoring solution for networks.
• ENV Probe - temperature and humidity monitoring module for
SNMP-NET and NV6 cards
• SSL Detection Modules:
SSL-EMD (temp/humidity), SSL-SMOKE,
SSL-WATER, SSL-VIBRATION, SSL-DOOR
SNMP Accessory Cards & Add-Ons
SNMP-NV6 / SNMP-NET / SNMP-SSL / NetAgent SNMP
Para Systems, Inc. | Minuteman Power Technologies
1455 LeMay Drive | Carrollton, Texas 75007 | 972.446.7363 | 800.238.7272
www.minutemanups.com | www.sizemyups.com
SNMP Option Slot
E2000RM2U UPS ENV PROBE SSL-EMD