Specifications

PUSH
TO
TALK
VOLUME
VOLUME
PUSH
TO
TALK
SILENCE
CALL/
CANCEL
DOOR
STATUS
DOOR
CONTROL
CALL/
CANCEL
DOOR
STATUS
DOOR
CONTROL
INMATE CALLS
LEVEL 2
LEVEL 3
TEST
POWER
CALL/
CANCEL
DOOR
STATUS
DOOR
CONTROL
CALL/
CANCEL
DOOR
STATUS
DOOR
CONTROL
FIRE
DOORS
DAYROOM
DOOR
DOOR
STATUS
LEVEL 2
LEVEL 3
LEVEL 1
LEVEL 3
LEVEL 2
LEVEL 1
GROUP
RELEASE
LEVEL 1 LEVEL 2 LEVEL 3
TELEPHONE
MONITORING
RECORD
OFFOFFOFF
OFFOFFOFFOFFOFFOFF
2423222120191817
CLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPEN
323130292827
26
25
CLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPEN
CLOSE OPEN
CLOSE OPEN
CLOSE OPEN
CLOSE OPEN
1
2
3
87654321
CLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPEN
161514131211109
CLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPEN
LEVEL
3
LEVEL
1
ALL
CALL
LEVEL
2
DAYROOM
DAYROOM
DOOR
LEVEL 1
PANEL 1 (LEFT) PANEL 1 (RIGHT)
SYSTEM E
SYSTEM A
SYSTEM D
SYSTEM A
SYSTEM H SYSTEM C
SYSTEM I
SYSTEM GSYSTEM F SYSTEM A
PUSH
TO
TALK
VOLUME
SILENCE
CALL/
CANCEL
DOOR
STATUS
DOOR
CONTROL
CALL/
CANCEL
DOOR
STATUS
DOOR
CONTROL
INMATE CALLS
LEVEL 1
LEVEL 3
TEST
POWER
CALL/
CANCEL
DOOR
STATUS
DOOR
CONTROL
CALL/
CANCEL
DOOR
STATUS
DOOR
CONTROL
FIRE
DOORS
DAYROOM
DOOR
DOOR
STATUS
LEVEL 2
LEVEL 3
LEVEL 1
LEVEL 3
LEVEL 2
LEVEL 1
2423222120191817
CLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPEN
323130292827
26
25
CLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPEN
CLOSE OPEN
CLOSE OPEN
CLOSE OPEN
CLOSE OPEN
87654321
CLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPEN
161514131211109
CLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPEN
LEVEL
3
LEVEL
1
ALL
CALL
LEVEL
2
DAYROOM
DAYROOM
DOOR
LEVEL 2
PANEL 2 (LEFT) PANEL 2 (RIGHT)
SYSTEM E
SYSTEM A
SYSTEM D
SYSTEM A
SYSTEM C
SYSTEM I
SYSTEM GSYSTEM F SYSTEM A
PUSH
TO
TALK
VOLUME
CALL/
CANCEL
DOOR
STATUS
DOOR
CONTROL
CALL/
CANCEL
DOOR
STATUS
DOOR
CONTROL
INMATE CALLS
LEVEL 1
LEVEL 2
SILENCETEST
POWER
CALL/
CANCEL
DOOR
STATUS
DOOR
CONTROL
CALL/
CANCEL
DOOR
STATUS
DOOR
CONTROL
FIRE
DOORS
DAYROOM
DOOR
DOOR
STATUS
LEVEL 2
LEVEL 3
LEVEL 1
LEVEL 3
LEVEL 2
LEVEL 1
323130292827
26
25
2423222120191817
CLOSE OPEN
CLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPEN
CLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPEN
CLOSE OPEN
CLOSE OPEN
CLOSE OPEN
161514131211109
87654321
CLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPEN
CLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPENCLOSE OPEN
LEVEL
3
LEVEL
1
ALL
CALL
LEVEL
2
DAYROOM
LEVEL 2
PANEL 3 (LEFT) PANEL 3 (RIGHT)
SYSTEM E
SYSTEM A
SYSTEM D
SYSTEM A
SYSTEM C
SYSTEM I
SYSTEM GSYSTEM F SYSTEM A
DAYROOM
DOOR
KEYED NOTES:
1. EXISTING CONTROL PANEL IS TO REMAIN UNDISTURBED.
2. EXISTING PART OF THE PANEL IS TO REMAIN FOR RE-USE.
3. EXISTING PART OF THE PANEL IS TO BE REPLACED.
4. RE-LABEL ALL WIRES AND CONNECTORS ON BOTH WIRE AND PANEL SIDES, AND THEN
DISCONNECT ALL WIRES AND DEVICES FROM THE PANEL. CUT THE PANEL ALONG THE DASHED
LINE AND REFINISH THE CUTTING EDGES.
5. RE-INSTALL PANELS BEING REUSED BACK IN PLACE.
1
32 5 4
1
32 5 4
1
32 5 4
GENERAL PROJECT NOTES:
1. THE SCOPE OF THE WASATCH D-BLOCK (THREE LEVELS) IS TO COMPLETELY UPGRADE THE
EXISTING PAGING SYTEM.
2. CONTRACTORS ARE REQUIRED TO VISIT THE JOBSITE, DOCUMENT EXISTING CONDITIONS
THAT WILL EFFECT FINAL CONSTRUCTION COSTS PRIOR TO FINAL BID.
3. REPLACE ALL NON-WORKING RELAYS AND POWER SUPPLIES SO THAT NEW AND EXISTING
CONTROL PANELS ARE COMPLETELY FUNCTIONAL.
4. INCLUDE AN ADDITIONAL 50% OF THE TOTAL QUANTITY OF ALL PUSH SWITCHES AND PUSH
BUTTONS, LED'S, KEY SWITCHES IN BID PRICE .
5. ALL AUDIO CABLES AND INTERCOM CABLES MUST BE INSTALLED IN CONDUITS. REUSE
EXISTING CONDUITS WHERE IT IS POSSIBLE AND INSTALL NEW CONDUITS WHERE IT IS
REQUIRED.
6. VERIFY SPECIFIED SPEAKERS WILL FIT THE EXISTING SPEAKER ENCLOSURES AND GRILLES
PRIOR TO ORDERING THE SPEAKERS. PROVIDE SPEAKER ADAPTERS TO COMPLETE
INSTALLATION IF NECESSARY.
7. NO CHANGES SHALL BE MADE WITHOUT THE AV CONSULTANT'S WRITTEN CONSENT.
8. PROVIDE THE OWNERS WITH A COPY OF THE CRESTRON PROGRAMING CODE UPON
COMPLETION OF THE PROJECT.
9. ALL NEW RELAYS, LEDs, PUSH BUTTONS, AND KEY SWITCHES SHALL BE WIRED USING
QUICK CONNECTIONS. NO SOLDERED CONNECTIONS ARE ALLOWED.
10. ALL LOW VOLTAGE SYSTEM WIRING IS SCHEMATIC. CONTRACTOR TO FIELD VERIFY THE
EXACT ROUTING AND LOCATIONS OF PENETRATIONS IN THE FIELD PRIOR TO ROUTING
CONDUIT AND CABLES.
11. WINNING CONTRACTORS ARE REQUIRED TO CONTACT THE OWNERS' REPRESENTATIVES
AND SCHEDULE THEIR WORKING HOURS TO BE DURING THE EVENING AND NIGHT TIMES FOR
MINIMAL CONTROL SYSTEM DOWN TIMES.
240 E. MORRIS AVE. SUITE 200
SALT LAKE CITY, UT 84115
P (801) 534-1130
F (801) 534-1080
www.envisioneng.com
1 2 3 4 5 6 7
A
B
C
D
E
F
1 2 3 4 5 6 7
A
B
C
D
E
F
ISSUE:
DATE:
DRAWN BY:
DESIGNED BY:
CHECKED BY:
PROJECT NO.:
ENVISION PROJECT NO.:
JW/GSN
JiLu
JO
APRIL 21, 2014
CONSTRUCTION DOCUMENTS
4/21/2014 4:56:18 PM
ETD122
WASATCH D-BLOCK
CONTROL PANEL
DEMO DETAILS
DRAPER PRISON WASATCH & OQUIRRH
INTERCOM & PAGING SYSTEM REMODEL
CD
.
14-003
1330410
SCALE:
NTS
ETD122
D-BLOCK LEVEL 1 CONTROL PANEL DEMO
1
SCALE:
NTS
ETD122
D-BLOCK LEVEL 2 CONTROL PANEL DEMO
2
SCALE:
NTS
ETD122
D-BLOCK LEVEL 3 CONTROL PANEL DEMO
3
NO. DATE REVISIONS
Bid DA14027DFCM
5/30/2014 2:08 PM p. 42