GENERAL DEMOLITION NOTES:
UNLESS SPECIFICALLY NOTED OTHERWISE, REMOVE ALL ELECTRICAL ITEMS SHOWN IN DARK & DASHED
LINES. LIGHT & SOLID ITEMS ARE TO REMAIN. DEMOLITION ITEMS ARE SHOWN TO GIVE A BASIC
DESCRIPTION OF THE EXTENT OF DEMOLITION WORK, BUT MAY NOT BE INCLUSIVE. PROVIDE
DEMOLITION WORK IN ACCORDANCE WITH THE FOLLOWING REQUIREMENTS:
1.1 REMOVE AND DISPOSE OF ALL RACEWAYS, BOXES, DEVICES, EQUIPMENT, ETC. THAT ARE NOT
TO BE REUSED.
1.2 EXISTING RACEWAYS MAY BE REUSED, IF IN PLACE, WHERE POSSIBLE, AND WHERE IN
COMPLIANCE WITH THE SPECIFICATIONS AND THE INTENT OF THE CONTRACT DOCUMENTS.
UPGRADE AND OR PROVIDE NEW CONDUIT SUPPORTS WHERE NECESSARY FOR ALL
RACEWAYS BEING REUSED. ENSURE INTEGRITY OF EXISTING RACEWAYS BEFORE REUSE.
1.3 DO NOT PENETRATE STRUCTURAL ELEMENTS OF FLOORS, WALLS, CEILINGS, ROOFS, ETC.
1.4 COORDINATE WITH OWNER WHAT EQUIPMENT SHOULD BE DISPOSED OF AND WHAT
EQUIPMENT IS TO BE RETURNED TO OWNER.
1.
2
TYP.
2
TYP.
1
3
2
TYP.
2
TYP.
2
TYP.
2
TYP.
1
3
2
TYP.
2
TYP.
2
TYP.
1
3
KEYED NOTES:
1. EXISTING PANELS, SEE SHEET EDT112 FOR DETAILS.
2. DISCONNECT, REMOVE AND RETURN SPEAKERS TO THE OWNERS. EXISTING SPEAKER
ENCLOSURES AND GRILLES TO REMAIN IN PLACE FOR REUSE. REMOVE CABLING ASSOCIATED
WITH SPEAKERS BACK TO EXISTING AMPLIFIERS COMPLETELY.
3. DISCONNECT, REMOVE AND RETURN EXISTING INTERCOM / PAGING AMPLIFIERS AND TONE
GENERATORS TO THE OWNERS.
GENERAL PROJECT NOTES:
1. THE SCOPE OF THE WASATCH D-BLOCK (THREE LEVELS) IS TO COMPLETELY UPGRADE THE
EXISTING PAGING SYTEM.
2. CONTRACTORS ARE REQUIRED TO VISIT THE JOBSITE, DOCUMENT EXISTING CONDITIONS
THAT WILL EFFECT FINAL CONSTRUCTION COSTS PRIOR TO FINAL BID.
3. REPLACE ALL NON-WORKING RELAYS AND POWER SUPPLIES SO THAT NEW AND EXISTING
CONTROL PANELS ARE COMPLETELY FUNCTIONAL.
4. INCLUDE AN ADDITIONAL 50% OF THE TOTAL QUANTITY OF ALL PUSH SWITCHES AND PUSH
BUTTONS, LED'S, KEY SWITCHES IN BID PRICE .
5. ALL AUDIO CABLES AND INTERCOM CABLES MUST BE INSTALLED IN CONDUITS. REUSE
EXISTING CONDUITS WHERE IT IS POSSIBLE AND INSTALL NEW CONDUITS WHERE IT IS
REQUIRED.
6. VERIFY SPECIFIED SPEAKERS WILL FIT THE EXISTING SPEAKER ENCLOSURES AND GRILLES
PRIOR TO ORDERING THE SPEAKERS. PROVIDE SPEAKER ADAPTERS TO COMPLETE
INSTALLATION IF NECESSARY.
7. NO CHANGES SHALL BE MADE WITHOUT THE AV CONSULTANT'S WRITTEN CONSENT.
8. PROVIDE THE OWNERS WITH A COPY OF THE CRESTRON PROGRAMING CODE UPON
COMPLETION OF THE PROJECT.
9. ALL NEW RELAYS, LEDs, PUSH BUTTONS, AND KEY SWITCHES SHALL BE WIRED USING
QUICK CONNECTIONS. NO SOLDERED CONNECTIONS ARE ALLOWED.
10. ALL LOW VOLTAGE SYSTEM WIRING IS SCHEMATIC. CONTRACTOR TO FIELD VERIFY THE
EXACT ROUTING AND LOCATIONS OF PENETRATIONS IN THE FIELD PRIOR TO ROUTING
CONDUIT AND CABLES.
11. WINNING CONTRACTORS ARE REQUIRED TO CONTACT THE OWNERS' REPRESENTATIVES
AND SCHEDULE THEIR WORKING HOURS TO BE DURING THE EVENING AND NIGHT TIMES FOR
MINIMAL CONTROL SYSTEM DOWN TIMES.
240 E. MORRIS AVE. SUITE 200
SALT LAKE CITY, UT 84115
P (801) 534-1130
F (801) 534-1080
www.envisioneng.com
1 2 3 4 5 6 7
A
B
C
D
E
F
1 2 3 4 5 6 7
A
B
C
D
E
F
ISSUE:
DATE:
DRAWN BY:
DESIGNED BY:
CHECKED BY:
PROJECT NO.:
ENVISION PROJECT NO.:
JW/GSN
JiLu
JO
APRIL 21, 2014
CONSTRUCTION DOCUMENTS
4/21/2014 4:55:59 PM
ETD111
WASATCH B-BLOCK
DEMO PLANS
DRAPER PRISON WASATCH & OQUIRRH
INTERCOM & PAGING SYSTEM REMODEL
CD
.
14-003
1330410
WASATCH B LEVEL 1 DEMO
1
WASATCH B LEVEL 2 DEMO
2
WASATCH B LEVEL 3 DEMO
3
NO. DATE REVISIONS
Bid DA14027DFCM
5/30/2014 2:08 PM p. 36