Specifications
2
INSPECTION
Carefully unpack and inspect your machine for shipping damage. Each unit is tested and
thoroughly inspected before shipment, and any damage is the responsibility of the delivery
carrier who should be notified immediately.
WARNING
• Read Instructions Manual before operating this piece of equipment.
• To reduce the risk of fire use only commercially available floor cleaners and waxes
intended for machine application
• Electrical motors and components can cause an explosion when operated near volatile
materials and vapors. Do not use this machine near flammable materials such as
solvents, thinners, fuels, grain dust, ect.
ELECTRICAL – 115 VOLT Model C8420-115
This machine is designed to operate on a standard 15 amp. 120-Volt, 60hz, AC circuit.
Voltages below 105-Volt AC or above 125-Volts AC could cause serious damage to the
motor.
ELECTRICAL – 240 VOLT Model C8420-240
This machine is designed to operate on a standard 16 amp. type L fused 230-Volt, 50 Hz,
AC circuit. Voltages below 200-Volt AC or above 250-Volts AC could cause serious
damage to the motor.
GROUNDING INSTRUCTIONS
• This floor finishing machine should be grounded while in use to protect the operator from
electric shock. The machine is equipped with a three-conductor cord and three prong
grounding type attachment plug to fit the proper grounding type receptacle. The green
(green and yellow) conductor in the cord is the grounding wire. Never connect this wire
to anything other than the grounding blade.
• Floor Finishing Machines Rated Less than 150-Volts – If the machine is provided with an
attachment plug, as shown in Sketch A, it is intended for use on a 120-Volt (normal)
circuit. If a properly grounded receptacle, as shown in Sketch A, is not available, an
adapter as shown in Sketch C, is available and be installed as shown in Sketch B if the
outlet box that houses the receptacle is grounded. Be sure to fasten the grounding tab
with the faceplate screw.
• Floor Finishing Machines Rated More than 150-Volts – If the machine is provided with
attachment plug as shown in Sketch D, it is intended for use in nominal 240-Volt circuit.
No adapter is available for this plug.