Installation guide
Keyword Reference Guide
MN1270 02.2002 77
FASTLATCHMODE/FTM
Purpose:
Sets the default action to be taken to clear the Encoders fast position latch.
Controllers Supported:
NextMove PCI NextMove PC NextMove BX MintDrive ServoNode 51
Format:
FASTLATCHMODE[axes] = <expression> {, <expression>, …}
v = FASTLATCHMODE[axis]
Dot Parameters:
Axis – Axis No.
Attributes:
Controller Read Write Command Multi-
Axis
Scaled Default Range
All
0
0 ≤ x ≤ 2
Description:
Controls the method of clearing the encoders fast position latch.
Mode Description
0 always re-capture position. Using this mode the data within the fast position register
will be updated on every activating edge on the appropriate fast interrupt line. The
latch is cleared automatically.
1 do not re-capture position until after the handler has completed. Using this mode the
data in the fast position register will remain unchanged whilst in the user installed
handler. When this handler exits the latch will automatically be cleared and enable
further latching. If a users handler has not been defined then the latch will be processed
as soon as the interrupt has been serviced.
2 do not re-capture position until the latch has been cleared manually. Using this mode
the register will remain unchanged until the user clears the latch manually using
FASTENABLE.
3 Disables the fast position latch for that axis.
See also:
FASTENABLE, FASTENCODER, FASTLATCH, FASTSELECT.
FASTSELECT/FS
Purpose:
Maps the Fast position capture to a specific fast input.
Controllers Supported:
NextMove PCI NextMove PC NextMove BX MintDrive ServoNode 51
Format:
FASTSELECT[axes] = <expression> {, <expression>, …}
v = FASTSELECT[axis]
Dot Parameters:
Axis – Axis No.