Installation guide

Mint™ v4 Advanced Programming Guide
66 MN1270 02.2002
Attributes:
Controller Read Write Command Multi-
Axis
Scaled Default Range
NextMove
0 any 16 bit integer
value
Description:
The Dual Port Ram is an area of Ram accessible by both the host PC and the controller, the size of this
depends on the controller. The
DPRFLOAT keyword allows the user to read and write 16 bit integer
values to any location within Dual Port Ram.
NextMove PCI
There is 4k of 32 bit wide Dual Port Ram on NextMove PCI, detail of the Dual Port Ram map can be
found in then Mint v4 PC Programming Guide. The valid address range on NextMove PCI is 0x0000 to
0x0FFD inclusive.
Care should be taken when writing 16 bit integer values to the dual port ram on NextMove PCI. The 16
bit value will not be sign extended and hence if it is not read back as a 16 bit value the perceived value
will be different.
NextMove PC
There is 1k of 16 bit wide Dual Port Ram on NextMove PCI, detail of the Dual Port Ram map can be
found in then Mint v4 PC Programming Guide. The valid address range on NextMove PC is 0x0 to
0x3FD inclusive.
See Also:
DPRLONG, DPRFLOAT
DRIVEPARAM/DRP
Purpose:
To get/set the value of the specified drive parameter.
Controllers Supported:
NextMove PCI NextMove PC NextMove BX MintDrive ServoNode 51
Format:
V = DRIVEPARAM.param
DRIVEPARAM.param = <expression>
Dot Parameters:
Param – drive parameter
Attributes:
Controller Read Write Command Multi-
Axis
Scaled Default Range
MintDrive,
ServoNode 51
Description:
Drive parameters are MintDrive and ServoNode 51 drive stage parameters. The DRIVEPARAM
keyword should not be used where an individual Mint keyword is available.
No. Parameter name Mint Keyword Range Factory
Default
Units
8 ServoNode 51 drive
type.
1 – brushed
7 – brushless
0 or 7 0