Example:
BACKLASH.3 = -0.3
BACKLASHINTERVAL.3 = 50
MOVER.3 = 0.5
GO.3
PAUSE IDLE.3
BACKLASHMODE.3 = 1
This sets up backlash compensation on axis 3 of 0.3 mm to be applied over 50 servo cycles. A small
negative move is performed to ensure that the backlash has been taken up in a positive direction;
equivalent to a negative direction home sequence.
The axis must be
idle in order to change the backlash mode and the default backlash mode is off.
See Also:
BACKLASH, BACKLASHINTERVAL, CONFIG
BUSVOLTAGE/BV
Purpose:
To read the DC bus voltage on a MintDrive.
Controllers Supported:
NextMove PCI NextMove PC NextMove BX MintDrive ServoNode 51
Format:
value = BUSVOLTAGE
Dot Parameters:
None.
Attributes:
Controller Read Write Command Multi-
Axis
Scaled Default Range
MintDrive
- 0 – 460V
Description:
Reads the DC bus voltage on a MintDrive. This is useful on an external 24V MintDrive to check that
the mains voltage is at the correct level before attempting motion.
If the bus voltage is below the bus voltage threshold, an error will be generated. This will be reported
by the
DRIVEFAULT keyword. The threshold below which an error is generated is controlled by the
BUSVOLTAGETHRESHOLD keyword.
Example
On a MintDrive with a 240V AC input, the DC bus voltage can be read as follows:
PRINT BUSVOLTAGE
338
The DC bus voltage is calculated as follows:
DC voltage = AC voltage x Ö2
See also: