Installation manual
www.baldormotion.com
Operation 5-15MN1933
4. If you are going to use the relay , drag the grey Relay0 icon to the grey X axis icon on the right
of the screen. To configure multiple axes to use the relay, repeat this step for the other axes.
If you are using a digital output, drag the bright blue OUT icon to the grey X axis icon on the
right of the screen. To configure multiple axes with the same drive enable output, repeat this
step for the other axes.
5. Click Apply at the bottom of the screen. This
sends the output configuration to the
NextMove PCI-2.
5.4.4 Testing the drive enable output
1. On the main Mint WorkBench toolbar, click
the Axes 0-7 button. In the Select Default
Axes dialog, select the axes to be controlled.
Click OK to close the dialog.
2. On the main Mint WorkBench toolbar, click
the Drive enable button. Click the button
again. Each time you click the button, the
drive enable output(s) for the selected axes
are toggled.
When the button is in the pressed (down)
position the drive amplifier should be
enabled. When the button is in the raised
(up) position the drive amplifier should be
disabled.
If this is not working, or the action of the button is reversed, check the electrical
connections between the breakout module and the drive amplifier.
If you are using the relay output, check that you are using the correct normally open or
normally closed connection.
If you are using a digital output, check that it is using the correct high, low , edge or rise/fall
triggering method expected by the drive amplifier.