Installation manual
www.baldormotion.com
Input / Output 4-5MN1933
NextMove PCI-2
-
+
Mint
ADC(0)
-
+
120k
120k
+12V
-12V
10k
10k
TL084
Breakout
module
3
1
2
100
way
cable
‘X6’
AIN0+
AIN0-
AGND
Figure 1 - Analog input wiring, AIN0 shown
For differential inputs connect input lines to AIN+ and AIN-. Leave AGND unconnected.
For single ended inputs, connect signal to AIN+. Connect signal ground to AIN- and AGND.
AIN0
1kΩ,0.25W
potentiometer
ADC(0)
3
2
X6
1.5 kΩ,0.25W
0V
+24 VDC
1