User Guide
Table Of Contents
- QMS magicolor 2 Print System Operation
- Contents
- Introduction
- Consumables
- Advanced Printing Features
- Color Printing
- Printer Care
- CrownView Printer Web Page
- Media Jams
- Troubleshooting Printer Problems
- Introduction
- Status and Service Messages
- HP-GL Error Codes and PCL Error Codes
- Testing PC-Printer Communication
- Testing Macintosh-Printer Communication
- Printer Problem Checklist
- OPC Belt Cartridge Problems
- Control Panel Problems
- Windows Driver Problems
- CrownNet Problems
- Output Problems
- Kanji Option Kit Problems
- Print Quality Problems
- Color Density Problems
- Image Defects
- Placing a Service Call
- Repacking the Printer
- QMS Customer Support
- Configuration Menu
- Index

Replacing the
Fuser Oil Bottle
and Cleaning
Roller
QMS magicolor 2 Op
eration5-16
7 Install the cleaning roller in
its slot.
The tab on the top of the
cleaning roller must be on the
left.
8 Close the two lock levers.
9 Close the printer’s top
cover.
10 Turn on the printer.
11 Reset the consumables
usage monitoring system.
a In the Operator Control/
Consumables/Item
Replaced/Fuser Oil menu
choose Yes.
b In the Operator Control/
Consumables/Item
Replaced/Cleaning Roller
menu choose Yes.
» Note:
When you replace the fuser oil bottle and cleaning roller
after a
FUSER OIL EMPTY
or
CHECK CLEANING ROLLER
message displays in the message window, the engine
automatically recovers. However, you must manually reset the
consumables usage monitoring system to ensure accurate
consumables monitoring.
To access consumables usage information, use the Operator
Control/Consumables/Print Statistics menu or the CrownView
printer web page.










