Specifications
QUANTUM-CALCULITE/PENTAX
METERS
312
Calcu-Lite XP (CLXP)
Gives fast, accurate measurement of
both reflected and incident light,
with an unusually wide measuring
range of EV -7 to EV +21. By rotating
the meter’s calculator dial to the light
reading, every usable shutter speed
and aperture combination can be
seen at a glance. This is invaluable
when determining depth-of-field.
With hi-low incident dome, strap,
case and batteries.
Item # CACLXP ......................
118.00
LIGHTMETERS
Quantum Digital Meter
MODEL CALCULITE XP
PHOTO CELL Blue Enhanced Silicon Photo Diode
MEASURING SYSTEM Ambient
DISPLAY READOUT Digital L.E.D.
FILM SPEED I.S.O. 0.5 to 50,000
F-STOP F0.7 to F181
SHUTTER SPEED 1/4000 sec. to 60 min.
CINE SPEED 8 to 128 F.P.S.
ANGLE OF COVERAGE REFLECTED LIGHT 30°
SENSITIVITY AT 100 I.S.O.
EV-7 to EV21
POWER SOURCE Four # 76 Batteries
DIMENSIONS
3.9 x 2.8 x 1.2” (100 x 70 x 30mm)
WEIGHT 4 oz. (112g)
Subject to change without notice
SPECIFICATIONS FOR DIGITAL FLASH METERS
Calcu-Lite Accessories
Calcu-Lite XP (CLXP)
®
S
M
SM
®
10° Spot Attachment (SX1)
Converts reflected light
measuring angle from normal
30° to 10° area spot. This is
accomplished without loss in
sensitivity.
Item # CASX1..................
52.50
Flat Diffuser (DX1)
Makes calibrated illuminance
measurements and contrast
measurements with studio
lighting.
Item # CADX1.................28.95
1˝ Rigid Fiber Optic Probe (FOX1)
1˝ rigid fiber optic probe; mea-
sures reflected light values of
1
⁄8˝ (3mm) diameter areas on
focusing screens, groundglass,
light tables and other luminant
objects. It serves as a densito-
meter for negatives and trans-
parencies with a resolution of
0.1 density units.
Item # CAFOX1...............
54.95
12˝ Flexible
Fiber Optic Probe
(FOX2)
Takes all the measurements of
1˝ Rigid Fiber Optic Probe
(FOX-1). Additionally, features
flexibility for difficult measure-
ments.
Item # CAFOX2...............
66.50
Swivel Studio Dome (SDX)
Takes incident light readings at
90° as opposed to 180° with
the standard turret.
Item # CASDX.................
66.50
Diffuser/Enlarging
Attachment
(DX2)
Can be used with a darkroom
enlarger or as a lux or footcan-
dle attachment similar to DX-
1, except with a swivel head.
Item # CADX2.................
57.95
Microscope Attachment (MX1)
Permits light readings through
a microscope eyepiece.
Item # CAMX1................
49.95
Flash Trigger Switch (FTS)
Item # CAFTS..................33.50
Hard Case (HC1)
Item # CACCF.................28.95
Standard Turret (ST)
Incident and reflected turret.
(Replacement.)
Item # CATS....................
12.95
Hi-Low Turret (HLT)
Item # CATHL.................11.95
Neck Strap (NS)
Replacement.
Item # CASN....................
11.95
PENTAX SPOTMETER V-FL
Spotmeter V-FL (36127)
The Spotmeter V-FL offers
1° spot exposure readings
directly in footlamberts.
Both the viewfinder scale
and the calculator dial are
calibrated directly in footlam-
berts (ft/L), eliminating the time
required for converting EV values into
footlamberts. The calculator dial fea-
tures
two scales
for easy calculation of
luminance ratio variations.
The Spotmeter V-FL incorporates all
of the technology and dependability of
the Spotmeter V - your assurance of
fast, precise measurement.
Item # PESM5FL......................
395.95
PHOTO CELL
Silicon Photo Diode
MEASURING SYSTEM
Spot Ambient Reading directly in Footlamberts
DISPLAY READOUT
Indicator Needle in Viewfinder
MEASURING RANGES
0.125 to 16,000 ft/L. Scene luminance
1.5:1 Luminance ratio 1:1 to 128000:1
VIEWFINDER
Single lens reflex pentaprism type with unreversed,
laterally correct image. Even illumination achieved
with finely grooved fresnel lens. 1° spot indicated in the
center of viewfinder. Field-of-view 21° diagonal,
17° horizontal and 12° vertical. Magnification 1.5x.
Adjustable eyepiece correction 0 to -1 diopter.
OTHER
Accepts 46mm filter and has a tripod socket
POWER SOURCE
Three 1.5v #76 Batteries
DIMENSIONS
2.5 x 6.4 x 5” (62 x 163 x 127mm)
WEIGHT
15.9 oz. (450g)
SPECIFICATIONS FOR SPOTMETER V-FL