Instruction manual
66 67
Specifications
Display range ISO: 3 to 8000 (1/3 stop increments)
Shutter speed (ambient)
:
30 min. to 1/8000 sec. (1, 1/2, 1/3 stop increments)
Shutter speed (flash)
: 1 sec. to 1/500 sec.
Frame rate
: 8 to 128 f/s
Exposure
: 1.0 to 90+0.9 stop (0.1 stop increments)
EV
: -17 to 40.8 (0.1 stop increments)
Exposure difference
: -10 to +10
(0.1 stop increments)
Analog scale
: FNO. 1.0 to 90 (1/2 stop increments)
Analyze scale
: Flash light proportion 0 to 100%
(25% increments)
Other functions Memory, exposure calculation, brightness difference
Flash light and ambient light proportion
measurement method (quadrant indicator)
Power One AA dry cell (alkaline dry cell, manganese dry
cell, nickel-cadmium rechargeable battery, nickel-
manganese dry cell, or lithium-manganese dry cell)
Battery life
Environment Temperature and relative humidity: -10°C (14°F) to
50°C (122°F), relative humidity 85% max. [at 35°C
(95°F)], no condensation
Storage -20°C to 55°C (-4°F to 131°F)
temperature range Relative humidity 85% max. [at 35°C (95°F)], no
condensation
Others Accessory-receptor jack (with cap)
Display correction function -10.0 to +10.0
(changeable between -0.8 to +0.7 per 0.1
increment)
Sync terminal
Dimensions 59 (W) x 147 (H) x 26 (D) mm
Weight 125 g
Standard accessories
Spherical Diffuser, neck strap, case
*Optional accessories
Viewfinder 5°, reflected-light attachment II, Mini
Receptor, Sync Cord III
● Specifications and external appearances described herein are subject to
change without notice.
Type Hand-held exposure meter for measuring ambient
and flash light
Reception method Incident-light and reflected-light readings
Receptors * optional accessory.
Incident:
Spherical Diffuser, Flat Diffuser*
Reflected:
Viewfinder 5° (angle 5°)*
Reflected-light attachment II (angle 40°)*
External receptor:
Mini Receptor*
• Light-reception speed automatic switching function
for incident-light and reflected-light readings
• 270° rotating receptor head
Receptor element Silicon photocell
Measuring modes AMBI:
Ambient light
CORD:
Flash light and flash bulb light using a sync
cord
NON CORD:
Flash light without a sync cord
Measuring range Ambient light
Incident: EV-2.0 to 19.9
(ISO100) Reflected-light attachment II:
EV2.5 to 24.4
Viewfinder 5°: EV2.5 to 24.4
Flash light
Incident-light readings:
FNO. 1.0 to 90+0.9 stop
Reflected-light attachment II:
FNO. 1.0 to 90+0.9 stop
Viewfinder 5°:
FNO. 1.0 to 90+0.9 stop
Repeatability ±0.1 stop
Calibration Incident: C=330 (Spherical Diffuser),
coefficient C=250 (Flat Diffuser)
Reflected: K=14
Specifications
AutoMeter_VF.qxd 02.7.8 1:31 PM ページ 66