Instruction manual

56 57
7
Press the memory button
to store the measurement
value.
8
Next, position the meter
by the subject and take a
reading with the Flat
Diffuser facing the fill light
source. When taking this
reading, block out all light
from the main light source
with your hands or other
means, so that it does not
directly fall on the Flat
Diffuser, or if possible,
turn off the main light
source.
The two pointers on the analog
scale indicate the brightness of
the main light source and the
brightness of the fill light source.
Read the difference in exposure
of the two values.
The reading accuracy of the
analog scale is 0.5 stops.
5
Set the display units to
FNo.
6
Position the meter by the
subject, and take a
reading with the Flat
Diffuser facing towards
the main (key) light
source.