Instruction manual

36 37
Basic OperationBasic Operation
If the flash does not fire within approx. one minute after the meter goes
into flash waiting mode, or if you press any button other than the
measuring button during this time, the NON CORD mode symbol will
stop blinking (stay on). Then, even if you fire the flash, no reading will be
made. To change back to flash waiting mode, press the measuring
button again.
Note that while in flash waiting mode, the meter may make incorrect
readings if it mistakes an intermittent light source such as fluorescent
lights as a flash, or if a reading is triggered mistakenly for any other
reason.
Fire the flash according to the directions given in the users' manual
for the flash.
If you change the shutter speed setting after taking a flash light
reading, the FNo. and quadrant proportion indicator will change
accordingly.
3
Use the up/down key to
set the desired shutter
speed.
Shutter speeds can be set
within the range of 1 sec. to
1/500 sec. (The speed should
be within the flash sync speed
range of your camera.)
Each time you press , the
shutter speed increases.
Holding down increases the
value continuously. The value
cannot be increased above
1/500 sec. even if you continue
pressing.
Each time you press , the
shutter speed decreases.
Holding down decreases
the value continuously. The
value cannot be decreased
below 1 sec. even if you
continue pressing.
4
Press the measuring
button and release it.
The NON CORD mode symbol
blinks to indicate that the meter
is waiting for the flash to take a
reading.
5
Fire the flash to take a
reading.
The meter detects the light of
the flash and reads and
displays the exposure on the
digital readout. The reading is
also displayed on the analog
scale.
To take further readings, repeat
the process from step 4.
AutoMeter_VF.qxd 02.7.8 1:31 PM ページ 36