Once the ATDC Sensor automatic adjustment is completed, varying T/C’s
may be compared with the UN8 output voltages as follows.
T/C
UN8 Output
Voltage
T/C
UN8 Output
Voltage
3.0% 3.17 V 6.0% 2.16 V
3.5% 3.00 V 6.5% 2.00 V
4.0% 2.84 V 7.0% 1.83 V
4.5% 2.67 V 7.5% 1.66 V
5.0% 2.50 V 8.0% 1.49 V
5.5% 2.33 V
<T/C Control Level Setting>
The T/C control level is set by AIDC Sensor control with reference to the
initial 5% at setting-up. (For details, see p. M-21.)Toner replenishing and
other controls are therefore provided so that the ATDC Sensor outputs are
according to the "T/C control level set by AIDC Sensor control."