Specifications
9-4. Ozone Filter
•
Ozone produced by the PC Drum Charge Corona is absorbed by the
Ozone Filter as the air is drawn out of the copier by Ventilation Fan Motor
M19.
•
This Ozone Filter is also used to absorb ozone produced by the Image
Transfer/Paper Separator Coronas from the air drawn out of the copier by
M19.
•
M19 is energized and deenergized by the output from pin 49 of IC5A on
PWB-A.
PC Drum Charge Corona
PC Drum Charge Corona Duct
Image Transfer/Paper
Separator Coronas
Ozone Filter
Rear of Copier
M19
<M19 Energization Timing>
M19 is energized at the same time when PC Drum Drive Motor M5 is
energized (see p. M-26).
<M19 Deenergization Timing>
M19 is deenergized approx. 4,600 msec. after the trailing edge of the last
copy has moved past Paper Exit Sensor PC36.
1075C05MAA