Specifications

9-4. Ozone Filter
Ozone produced by the PC Drum Charge Corona is absorbed by the
Ozone Filter as the air is drawn out of the copier by Ventilation Fan Motor
M19.
This Ozone Filter is also used to absorb ozone produced by the Image
Transfer/Paper Separator Coronas from the air drawn out of the copier by
M19.
M19 is energized and deenergized by the output from pin 49 of IC5A on
PWB-A.
PC Drum Charge Corona
PC Drum Charge Corona Duct
Image Transfer/Paper
Separator Coronas
Ozone Filter
Rear of Copier
M19
<M19 Energization Timing>
M19 is energized at the same time when PC Drum Drive Motor M5 is
energized (see p. M-26).
<M19 Deenergization Timing>
M19 is deenergized approx. 4,600 msec. after the trailing edge of the last
copy has moved past Paper Exit Sensor PC36.
1075C05MAA
M-33