Specifications

2-27. C0F30: ATDC Sensor UN8 Failure
C0F31: ATDC Sensor UN8 Failure
Step Check Item Result Action
1
Is the value for "Set" of "ATDC Level" of
"Level History" equal to the value given on
the Adjust Label?
NO
Enter the value given on the
Adjust Label.
2
After the Power Switch has been turned ON,
is the voltage across PJ6A-5 on PWB-A and
GND in the range DC0.18V to DC4.52V?
YES
Change PWB-A.
NO
Check that PJ6A and CN99
have been plugged in.
Change UN8.
PWB-A
CN99
UN8
Symbol Name
UN8
PWB-A
ATDC Sensor
Master Board
1075C26TAA
T-120