Specifications

C0996
Step Check Item Result Action
1
Check the operation of the 3rd Drawer Lock
Solenoid SL8 as described below:
 
1) Reset the malfunction.
2) Select "IC Port Data Check".
3) <Metric Areas>
Is the data of PC3 on PWB-F (3MJ)
(IC1F) "1" (SL8: deenergized)?
(See the 4/8 Screen on T-7.)
<Inch Areas>
Is the data of PC3 on PWB-F (3MC)
(IC1F) "1" (SL8: deenergized)?
(See the 5/8 Screen on T-7.)
NO
Change PWB-F or PWB-A.
4) By pressing the "Change" key to change
the data from "1" to "0", does SL8
operate? (Make sure that SL8 makes a
sound.)
YES
Check the Drawer Lock
mechanism.
NO
Change SL8.
2
Do as described below to check the 3rd
Drawer Set Sensor PC61 when the 3rd
Drawer is slid in:
 
1) Select "IC Port Data Check".
2) <Metric Areas>
Is the data of PG2 on PWB-F (3MJ)
(IC2F) " "?
(See the 5/8 Screen on T-7.)
<Inch Areas>
Is the data of PG2 on PWB-F (3MC)
(IC2F) " "?
(See the 6/8 Screen on T-7.)
NO
Check the 3rd Drawer Set
Detecting Plate.
3) Remove the Lower Rear Door and
forcibly unlock the 3rd Drawer with a
screwdriver to push it out. (PC61: not
blocked)
 
4) Select "IC Port Data Check" again.
<Metric Areas>
Has the data of PG2 on PWB-F (3MJ)
(IC2F) changed from " " to " "?
<Inch Areas>
Has the data of PG2 on PWB-F (3MC)
(IC2F) changed from " " to " "?
YES
Change PWB-F or PWB-A.
NO
Change PC61.
L H
L
L H
L
T-110