Specifications

C0998, C0999
Step Check Item Result Action
1
Slide out the 3rd Drawer and check the 3rd
Drawer Shifter Return Position Sensor PC48
as described below:
 
1) Select "IC Port Data Check".
2) <Metric Areas>
Is the data of PB1 on PWB-F (3MJ)
(IC2F) " "?
(See the 5/8 Screen on T-7.)
<Inch Areas>
Is the data of PB1 on PWB-F (3MC)
(IC2F) " "?
(See the 6/8 Screen on T-7.)
NO
Check the position of the
Shifter.
3) With the 3rd Drawer slid out, lift up the
Main Tray to unblock PC48.
 
4) Select "IC Port Data Check" again.
<Metric Areas>
Has the data of PB1 on PWB-F (3MJ)
(IC2F) changed from " " to " "?
<Inch Areas>
Has the data of PB1 on PWB-F (3MC)
(IC2F) changed from " " to " "?
YES
Change PWB-F or PWB-A.
NO
Change PC48/PWB-H.
H L
H
H L
H
T-107