Specifications
∗
C0911 (Inch Areas)
Step Check Item Result Action
1
Slide out the 2nd Drawer and check the 2nd
Drawer Lift-Up Sensor PC15 as described
below:
1) Select "IC Port Data Check".
2) Is the data of PE3 on PWB-F (3MC)
(IC2F) " "?
(See the 6/8 screen on T-7.)
NO
•
Check the Paper Take-Up Roll
Assy.
3) Slide the 2nd Drawer back in and press
the 2nd Drawer Paper Descent Key to
complete lift-up. (PC15: blocked)
4) Select "IC Port Data Check" again. Has
the data of PE3 on PWB-F (3MC) (IC2F)
changed from " " to " "?
YES
•
Change PWB-F or PWB-A.
NO
•
Change PWB-M2 or PC15.
∗
C0912, C0913 (Inch Areas)
Step Check Item Result Action
1
Check the 2nd Drawer Lower Limit Position
Sensor PC50 as described below:
1) Select "IC Port Data Check".
2)
<PC50 is blocked>
Is the data of PF3 on PWB-F (3MC)
(IC2F) " "?
(See the 6/8 screen on T-7.)
YES
•
Change PWB-F or PWB-A.
NO
•
Change PWB-M2 or PC50.
3)
<PC50 is not blocked>
Is the data of PF3 on PWB-F (3MC)
(IC2F) " "?
(See the 6/8 screen on T-7.)
YES
•
Change PWB-F or PWB-A.
NO
•
Change PWB-M2 or PC50.
∗
C0916 (Inch Areas)
Step Check Item Result Action
1
Remove the Right Door, push the Lock
Lever forward with a flat- blade screwdriver
to unlock and slide out the 2nd Drawer.
2
Is the Lock Release Spring Installed
properly?
NO
•
Reinstall or change.
3
Are the Lock Lever and Torsion Spring
installed properly?
NO
•
Reinstall or change.
H
H L
H
L
T-100